Fan option
Fan population guidelines
The number of fans installed in the server determines fan redundancy.
Configuration
Fan
redundancy
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
Bay 6
One processor,
without NVMe drives
and rear 2-SFF
drives installed
No
Blank
Blank
Blank
Fan
Fan
Fan
One processor,
without NVMe drives
and rear 2-SFF
drives installed
Yes
Blank
Fan
Blank
Fan
Fan
Fan
One processor, with
NVMe drives or rear
2-SFF drives
installed
No
Blank
Fan
Fan
Fan
Fan
Fan
One processor, with
NVMe drives or rear
2-SFF drives
installed
Yes
Fan
Fan
Fan
Fan
Fan
Fan
Two processors
No
Blank
Fan
Fan
Fan
Fan
Fan
Two processors
Yes
Fan
Fan
Fan
Fan
Fan
Fan
Fan mode behavior
• In nonredundant fan mode, a fan failure or a missing fan causes:
◦ The system Health LED to flash amber.
◦ The operating system to orderly shutdown.
• In redundant fan mode:
◦ A fan rotor failure will switch the system to nonredundant fan mode.
This change is indicated by the Health LED flashing amber. The system continues to operate
normally in this mode.
◦ A second fan rotor failure or a missing fan causes the operating system to orderly shutdown.
86
Hardware options installation
Summary of Contents for ProLiant DL180
Page 30: ...24 bay SFF hot plug drive model Fan bay numbering 30 Component identification...
Page 58: ...SFF 4 Install the drive LFF SFF 58 Hardware options installation...
Page 97: ...Secondary riser cage Slot 4 Slot 5 or 6 Hardware options installation 97...
Page 128: ...Box 2 to type a controller Box 2 to type p controller 128 Cabling...
Page 129: ...Box 3 to system board Box 3 to type a controller Cabling 129...
Page 130: ...Box 3 to type p controller 8 bay SFF power cable default 130 Cabling...
Page 135: ...Mini SAS cable to SAS expander Cabling 135...
Page 137: ...M 2 SSD enablement board installed in secondary riser Cabling 137...
Page 142: ...Cable routing Serial port Cable routing iLO Service Port SFF LFF 142 Cabling...
Page 144: ...Secondary riser cage Slot 4 Slot 5 or 6 144 Cabling...