Installation
C-37
Configuring a Library System
All Libraries are factory-shipped as stand-alone units. To include them in a multi-unit Library
system, you must first configure one unit as the master and all other units as slaves. Any Library
can be configured to be a standalone, master, or slave.
The Master Unit
The master unit controls the operations of a multi-unit Library system. All configuration
changes to the system are performed at the operator panel of the master unit.
NOTE:
In a storage cabinet, the master unit must occupy the top position to coordinate the action of the
Pass-Through Mechanism (PTM).
To configure the master unit:
1.
From the Default screen, press Enter
Enter
Enter
Enter to display the main menu.
u
Load/Unload
Remove Magazine
Maintenance Menu
Configure Menu
¤
2.
Press the
q
button three times to move the
u
to the Configure menu, then press the Enter
Enter
Enter
Enter
button. The following Configure submenu appears. The
¤
at the end of the fourth line
means you can scroll to additional configuration options using the
q
button.
u
SCSI Options
Library Options
Barcode Options
Set Element Base
¤
3.
Press the
q
button to move the
u
to Library Options, then press the Enter
Enter
Enter
Enter button. The
following screen appears:
u
Configuration
*Standalone
Unload Mode
*Implicit
¤
4.
Press Enter
Enter
Enter
Enter to move the cursor to the second line.
5.
Use the
q
and
p
buttons to change the option to Master.
6.
Press Enter
Enter
Enter
Enter to save the selection.
NOTE:
The change will not take effect until you reboot.