6-4
Firmware
P05957-002
6.3.2 Using the SUMTool to flash the BMC
Use the
sum
command to use SUMTool to flash the BMC.
In-band:
1. Upload the new BMC file to the server.
2. Run the
sum
command to flash the firmware:
#
sum -c UpdateBmc --file <
bmc_filename
> --overwrite_cfg --overwrite_sdr
3. When flashing is complete, AC power cycle the server.
Out-of-band:
1. Upload the new BMC file to a remote server.
2. Run the
sum
command to flash the firmware:
#
sum -i <
hostname
> -u <
username
> -p <
password
> -c UpdateBmc --file
<
bmc_filename
> --overwrite_cfg --overwrite_sdr
3. When flashing is complete, AC power cycle the server.
6.3.3 Using the Web GUI to flash the BMC
1. Log in to the Web GUI.
2. Go to the
Maintenance
tab and click
Firmware Update
.