8.2.2 Starting the machine
1.
NOTICE!
Irreparable damage to the starter!
Improper operation can damage the starter irreparably.
➤ Do not activate the starter switch when the engine is still running.
➤ Do not turn and hold the starter switch for longer than 30 seconds.
➤ Wait for a few minutes after each attempt to start the machine.
➤ The ignition switch must be returned to the neutral position before each start attempt (re‐
start protection).
2. Turn the «ignition switch»
5
to the “I” position.
The
charging indicator lamp should illuminate.
3. Turn the «ignition switch» to the “II” position and hold in place (max. 5-10 seconds).
The glow plugs are activated and the diesel engine preheated.
4. Turn the «ignition switch» to the “III” position and release it as soon as the engine starts.
The
charging indicator lamp is extinguished as soon as the engine is running.
If the charging indicator lamp is not extinguished, a fault has occurred. See chapter 9.2.
The electric fuel pump starts automatically during preheating. This vents the fuel lines before
each start.
The maximum preheating time should be 5-10 seconds.
8.2.3 Running the machine up to operating temperature
To avoid needless wear, the engine should be run in IDLE until the airend discharge temperature
has r30 °C. The airend discharge temperature is displayed by the remote contact ther‐
mometer on the control panel.