Chapter 3 - Installing the Array
44
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
To install the cable management arm:
1.
At the rear of the chassis, remove the shoulder screws and shims from the
rear equipment frame mounting bracket and set aside. Orient the cable
management arm mounting bracket on the right, as illustrated in the figure
below.
Figure 3.3 Installing the Cable Management Arm Mounting Bracket
2.
Align the thumb screws on the cable management arm mounting bracket
with the installation holes on the right rear of the chassis. Securely tighten
the thumb screws into the chassis.
3.
Using the four (4) shoulder screws and shims that were set aside in step 1,
secure the cable management arm mounting bracket to the rear
equipment frame mounting bracket, placing the shim between the shoulder
screws and the cable management arm mounting bracket, with the
enclosed Hex key. The cable management arm mounting bracket slides the
arm forward and enables the chassis to be fully extended from the
equipment rack for accessibility.
4.
At the rear side of the system, using the two (2) SEM 10-32 x 0.50 screws
included in the shipping package, secure the cable holder to the equipment
rack over the rear equipment frame mounting bracket on the right side of
the system as illustrated in the figure below.