![HP VMA Series Installation And Service Manual Download Page 31](http://html.mh-extra.com/html/hp/vma-series/vma-series_installation-and-service-manual_159708031.webp)
System Specifications
HP-AM456-9002A Rev 01
VMA-series Memory Array Installation and Service Guide
31
System Specifications
The table below lists the Memory Array system specifications.
Direct-attached Host Computer Requirements
The table below lists the minimum requirements for a direct-attached host
computer used with the Memory Array.
Table 1.3 System Specifications
Specification
Description
Electrical
Input Power Voltage: 120 V or 240 V
Current Capacity: 12 A @ 120 V or 7 A @ 240 V
Environmental
Ambient Operating Temperature: 5 °C to 35 °C
Short Term: -5 °C to 40 °C
Operating Humidity: 5 to 85% (Non-Condensing)
Short Term: 5 to 90% (Non-Condensing)
Interfaces
x8 PCIe Interface (2)
Note:
When both PCIe interfaces are used they become
x4.
Serial Interface via DB-9 male DTE port
10/100 Ethernet port
Logging
Syslog
Management
CLI: Serial, Telnet, SSH
Physical
Height: 5.19" (3U/132 mm)
Depth: 28.38" (721mm)
Width: 16.915" (430mm)
Minimum Rear Clearance: 7" (178mm)
Maximum Weight: 76 lbs (34.5 kg)
Table 1.4 Direct-attached Host Computer Requirements
Minimum Requirements
Intel/AMD x86 or x86_64 computer
An available PCIe slot that communicates with the processor. Slots capable of
bidirectional x8 PCIe provide the best performance.