Action
Replace the cleaning cartridge with a new cartridge.
A particular cartridge sets off the attention LED and possibly the cleaning
LED
Symptom
A particular cartridge sets off the attention LED and possibly the cleaning LED.
Action
1.
Retry the operation with a different cleaning cartridge.
2.
If the attention LED is cleared and the drive has been cleaned, and then immediately redisplays each
time a particular cartridge is reloaded, the cartridge is likely defective.
a.
Export the cartridge and load a known good cartridge.
In some cases, a cartridge can be worn out, have a defective Cartridge Memory, or have been
formatted as a Firmware Upgrade Cartridge.
b.
Do NOT reuse any cartridge that is suspected of being defective or contaminated in any drive.
c.
If the bad cartridge is a cleaning cartridge, it might be expired.
The library displays incorrect barcodes
Symptom
The library displays incorrect barcodes.
Action
1.
Verify that the label is a Hewlett Packard Enterprise label. The barcode reader might not be able to
read other labels.
2.
Verify that the label is properly applied.
3.
Verify that the label is not soiled.
Cannot connect to the RMI
Symptom
You cannot connect to the RMI from a browser.
Action
1.
Verify that the Ethernet cable is connected to the base module controller board and to the LAN.
2.
Verify that the link LED on the RJ45 (LAN) connector is illuminated.
The library illuminates the link LED when the library is powered on. If the LED is not illuminated, the
library is not communicating with the LAN. See your network administrator for help.
A particular cartridge sets off the attention LED and possibly the cleaning
LED
175