1.
From the Home screen, press
Previous
or
Next
until the screen displays
Configuration
. Press
Enter
to select.
2.
Press
Previous
or
Next
until the screen displays
Configure Auto Cleaning
. Press
Enter
to select.
3.
The screen displays
Auto Cleaning Disabled
or
Auto Cleaning Enabled
depending on the current
setting. To change the auto cleaning configuration, press
Enter
.
4.
Press
Previous
or
Next
until the screen displays the configuration you want. Press
Enter
.
Restoring factory defaults (Configuration > Restore Defaults)
The device can reset most of the configurations to the factory defaults, while retaining the settings
necessary to use the RMI. The device will perform an inventory after the defaults are restored.
The restored settings are:
•
SCSI addresses: The SCSI ID for the bottom drive is 4; the SCSI ID for the top drive is 5. The Library
will no longer recall a drive that has been removed.
•
Fibre Channel drive configuration: Automatic speed, auto port type
•
Master drive: reset to Drive 1 or the lowest numbered existing drive
•
Drive power: all drives powered on
•
Active slots: maximum possible
•
Library mode: Automatic
•
Loop: No
•
Event log levels and filter: continuous trace and all levels and filters active (for HP Service use only)
•
Barcode reader label length: 8
•
Barcode reader alignment: Left
•
Error recovery: On
•
Mailslot configuration: mailslot disabled
•
Auto clean: disabled
•
SNMP: disabled, but saved addresses to not change
•
E-mail notification: disabled, but configurations retained
The following settings are not reset:
•
Administrator password
•
Network settings (network is always enabled)
•
Date and time
To restore the factory defaults:
1.
From the Home screen, press
Previous
or
Next
until the screen displays
Configuration
. Press
Enter
to select.
2.
Press
Previous
or
Next
until the screen displays
Restore Defaults
. Press
Enter
to select.
Saving and restoring the Library configuration (Configuration > Save/Restore Configuration)
Use this option to save the configuration settings to a USB flash drive. The saved configuration
information will make it easier to recover the device configuration if you need to replace the chassis.
This feature is also useful when installing multiple devices. Either save the configuration before
configuring the network or ensure that only one device with the same network configuration is on the
network at a time until they have unique network identities.
Operating the Tape Library
120
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...