Diagnostics
46
Edge Switch 2/12 Service Manual
Does the Status field display a
Failed
message for the power supply?
NO
YES
↓
The power supply failed. Replace the switch. Exit MAP.
The switch appears operational. Exit MAP.
MAP 0200: POST Failure Analysis
When the switch is powered on, it performs a series of power-on self-tests
(POSTs). When POSTs complete, the switch performs an initial machine load
(IML) that loads firmware and brings the unit online. This MAP describes fault
isolation for problems that may occur during the POST/IML process.
If an error occurs, the POST/IML process continues in an attempt to initialize the
switch and bring it online. An event code 400 displays when the switch completes
the POST/IML process.
1
Ensure the switch reporting the problem is connected to facility AC power.
Inspect the switch for indications of being powered on, such as:
■
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
■
Illuminated LEDs adjacent to Fibre Channel ports.
■
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES
NO
↓
An AC power distribution problem is indicated, and analysis for the
failure is not described in this MAP. Go to “
” on page 43. Exit MAP.
2
Was an event code 400 or 411 observed at the EWS Event Log?
YES
NO
↓
Analysis for the failure is not described in this MAP. Go to “
” on page 32. Exit MAP.