Event Codes
155
Edge Switch 2/12 Service Manual
CTP Card Events (400 through 499)
Table 47: Event Code 400
Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a faulty field replaceable unit (FRU) as
indicated by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure
is indicated, replace the switch. Perform the procedure described in “
Event Data:
Byte
0
= FRU code as follows:
02
= CTP card,
05
= cooling fan,
06
= power supply
assembly.
Byte
1
= FRU slot number.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
Table 48: Event Code 410
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can
occur automatically after a firmware fault (event code
411
), or be user-initiated.
Event data indicates the type of reset.
Action:
No action required.
Event Data:
Byte
0
= reset type as follows:
00
= power-on,
02
= IML,
04
= reset.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔