System board LED
and color
Internal Health
LED Color
Status
Red
One or more of the following conditions
may exist:
•
Processor in socket X has failed.
•
Processor in socket X failed over to
the of
fl
ine spare.
•
Processor X is not installed in the
socket.
•
Processor X is unsupported.
•
ROM detects a failed processor
during POST.
Processor failure,
socket X (Amber)
Amber
Processor in socket X is in a pre-failure
condition.
Processor failure,
both sockets (Amber)
Red
Processor types are mismatched.
PPM failure (Amber)
Red
PPM has failed.
DIMM failure, slot X
(Amber)
Red
•
DIMM in slot X has failed.
•
DIMM in slot X is an unsupported
type, and no valid memory exists in
another bank.
Amber
•
DIMM in slot X has reached single-bit
correctable error threshold.
•
DIMM in slot X is in a pre-failure
condition.
•
DIMM in slot X is an unsupported
type, but valid memory exists in
another bank.
DIMM failure, all
slots in one bank
(Amber)
Red
No valid or usable memory is installed
in the system.
Amber
The Health Driver has detected a
cautionary temperature level.
Overtemperature
(Amber)
Red
The node has detected a hardware
critical temperature level.
Riser interlock
(Amber)
Red
The PCI riser board assembly is not
seated.
Online spare
memory (Amber)
Amber
Bank X failed over to the online spare
memory bank.
Power converter
module interlock
(Amber)
Red
The power converter module is not
seated.
Fan module (Amber) Amber
A redundant fan has failed.
Fan module (Red)
Red
The minimum fan requirements are not
being met in one or more of the fan
modules. One or more fans have failed
or are missing.
Power supply signal
interlock (Amber)
Red
The power supply signal cable is not
connected to the system board.
124
Component identi
fi
cation
Summary of Contents for StorageWorks 300
Page 18: ...18 Introduction ...
Page 50: ...50 Operation ...
Page 60: ...60 User interfaces ...
Page 86: ...86 Configuration ...
Page 98: ...98 Management ...
Page 118: ...1 18 CLI command set ...
Page 128: ...128 Component identification ...
Page 142: ...142 Component replacement ...
Page 150: ...150 Troubleshooting ...
Page 161: ...Latvian notice Lithuanian notice Polish notice HP StorageWorks 161 ...
Page 170: ...170 Specifications ...
Page 176: ...176 Glossary ...