Diagnostics
50
■
An illuminated green LED on the active CTP card, and illuminated green
PWR OK LEDs on both power supplies.
■
Audio emanations and airflow from cooling fans.
Is the director powered on?
YES
NO
↓
A power distribution problem is indicated. Go to
to obtain
event codes. If no event codes are found, go to “
” on page 69. Exit MAP.
9
At the director, inspect the amber LED at the top of each CTP card.
Is the amber LED illuminated on both CTP cards?
NO
YES
↓
Failure of both CTP cards is indicated. Event codes are not recorded.
Go to “
MAP 0500: FRU Failure Analysis
” on page 107. Exit MAP.
10
A director-to-HAFM appliance Ethernet link failure is indicated.
to obtain event codes. If no event codes are found, go to “
0400: Loss of HAFM Appliance or Web Browser PC Communication
page 92. Exit MAP.
11
Does a red diamond with yellow background (failure indicator) display as the
background to the icon representing the director reporting the problem?
YES
NO
↓
12
Double-click the icon representing the director reporting the problem. The
Hardware View displays. At the Hardware View:
■
Observe the director Status table is yellow and the director status is NOT
OPERATIONAL.
■
Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator)
that overlays the FRU graphic.
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...