Event Code Tables
379
SBAR Assembly Events (600 through 699)
Event Code: 600
Message:
SBAR assembly hot-insertion initiated.
Severity:
Informational
Explanation:
Installation of a backup SBAR was initiated with the director powered on and
operational. The event indicates that operational firmware detected the presence of
the SBAR, but the SBAR is not seated. When the SBAR is seated in the director
chassis and identified by firmware, an event code 601 is generated.
Action:
If event code 601 follows this event and the amber LED on the SBAR assembly
extinguishes, the replacement SBAR assembly is installed and no additional action
is required. If event code 601 does not follow this event, re-seat the SBAR assembly.
If event code 601 still does not display, replace the SBAR assembly.
Event Data:
Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 601
Message:
SBAR assembly recognized.
Severity:
Informational.
Explanation:
An SBAR assembly is installed and recognized by director operational firmware.
Action:
No action required.
Event Data:
Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...