Error Code
Audible
Beeps
Probable Source of
Problem
Action
209-Online Spare
Memory
Configuration-Spare
bank is invalid. Mixing
of DIMMs with
Primary Width of x4
and x8 is not allowed
in this mode.
1 long,
1 short
Installed DIMMs for
online spare bank are of
a different primary width
than the DIMMs in other
banks.
Install or reinstall DIMMs to
support online spare
configuration.
209 - Mirror Memory
Configuration -
DIMMs on both
boards do not match.
1 long,
1 short
Memory boards are not
populated identically, or a
memory board is missing.
Be sure that two memory
boards are installed and that
DIMMs are populated
correctly.
209 - Mirror Memory
Configuration -
Single-Board Mirror
DIMMs do not match.
1 long,
1 short
Mirrored banks are not
populated identically, or
memory board 1 is
missing.
Be sure mirrored banks are
populated identically and that
only memory board 1 is
installed.
209-Mirror Memory
Configuration - Board
2 present in Single-
Board Mirror.
1 long,
1 short
A second memory board
is installed in the single-
board mirrored memory
configuration.
Remove memory board 2.
211-Invalid Processor
Board PPM installed,
Module
X
None
Wrong PPM installed.
Replace processor PPM.
211-Invalid Processor
PPM installed,
Module
X
None
Wrong PPM installed.
Replace processor PPM.
211-Invalid Voltage
Regulator Module
installed for Processor
X
None Nonredundant
Processor
Power Module (PPM)
installed in indicated
processor slot.
Replace with a PPM that
supports redundancy.
212-Processor Failed,
Processor
X
1 short
Processor in slot
X
failed.
Run Diagnostics and replace
failed processor.
212-System
Processor
Failed/Mapped out
1 short
Processor in slot
X
failed.
Run Diagnostics and replace
failed processor.
continued