Removal and replacement procedures 28
4.
Place the server on a flat, level work surface.
Install the service tray
CAUTION:
To prevent improper cooling and thermal damage, operate servers only when the
open side of the server is enclosed by either another server, a divider, or the chassis wall.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the chassis
unless all bays are populated with a component or a blank.
IMPORTANT: To maintain proper airflow for odd-numbered servers, use the service tray
during even-numbered server servicing events only. This tray is not intended for use during
normal server operation.
Install the component as indicated.
Remove the I/O module
1.
Power down the server associated with the I/O module ("
2.
Remove the server associated with the I/O module ("