background image

 

 

HP ProLiant SL165s G7 Server 

Installation Instructions 

 

 

 

 
 
 
 
 
 
 
 
 
 

 

 
 
 

 
 

 
 

 
 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 
 

Part Number 635251-002 

 

Summary of Contents for ProLiant SL165s

Page 1: ...HP ProLiant SL165s G7 Server Installation Instructions Part Number 635251 002 ...

Page 2: ...500 chassis with 4 SL165s G7 servers Item Description 1 UID LED Switch 2 Serial port 3 Top NIC4 Connector Bottom NIC3 Connector 4 Server 1 5 Server 2 6 Server 3 7 Power LED Switch 8 Health LED 9 NIC1 Connector 10 NIC2 Connector 11 Server 4 12 VGA port 13 Mgmt NIC Optional 14 Top USB 2 0 Port Bottom USB 2 0 Port 15 SD card slot Optional ...

Page 3: ...J103 DIMM slot 1 for processor 1 7 J210 DIMM slot 12 for processor 2 8 U2 Processor 2 9 J54 4 pin power connector 10 J52 24 pin power connector 11 J61 Fan connector 1 12 J62 Fan connector 2 13 J203 DIMM slot 1 for processor 2 14 J68 Backplane I2 C connector 15 J53 8 pin power connector 16 J63 J64 Fan connectors 3 4 17 J65 Fan connector 5 18 J49 Internal USB 2 0 port 19 J8 Front panel USB 2 0 port ...

Page 4: ...tem of your choice For detailed procedures refer to the documentation provided by the operating system vendor For a list of operating systems supported by your ProLiant server go to http www hp com go supportos Pre and Post installation Procedures When installing additional options in your HP ProLiant SL165s G7 Server observe the following procedures Pre installation procedures 1 Turn off the serv...

Page 5: ...ith SR DR DIMM Memory Socket 2 8 5 11 1 7 4 10 3 9 6 12 NOTE SR Single Rank DR Dual Rank QR Quad Rank Population rules must be followed for both processors Memory modules may be populated one at a time per processor but populating two at a time per processor provides better performance Memory modules should be populated four at a time per processor for best performance Quad Rank memory module can ...

Page 6: ...ing holes 2 Tighten the mounting pins clockwise to secure the heat sink connection to the system board CAUTION To prevent the heat sink from tilting to one side during installation removal turn each screw a couple of turns alternatively between both of them and then apply the final torque Do not over tighten the spring loaded screws to prevent them from breaking off A maximum torque of 4 5 inch lb...

Page 7: ...Installing the CPU Air Baffle NOTE The CPU air baffle is required for proper thermal solution To install the CPU air baffle 1 Align the CPU air baffle to the tray 2 Secure the left latch to the left bracket the middle latch to the middle bracket and the right latch to the PCIe x16 bracket on the tray 3 Press down the CPU air baffle to make sure it completely installed on the tray Figure 13 Install...

Page 8: ...r HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Part Number 635251 002 February 2011 Second Edition Printed in China 635251 002 635251 002 ...

Reviews: