Removal and replacement procedures 62
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives, power
input modules, and the internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any system installation. Improper grounding can cause
electrostatic discharge.
To remove the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Remove the access panel ("
5.
Disconnect all cables connected to existing expansion boards.
6.
Remove the PCI riser cage (on page
7.
Remove any existing expansion board from the riser board.
8.
Remove the riser board from the cage.