Environmental specifications
Specification
Value
Temperature range*
—
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Nonoperating
-30
°
C to 60
°
C (-22
°
F to 140
°
F)
Relative humidity
(noncondensing)
—
Operating
Minimum to be the higher (more moisture) of
-12°C (10.4°F) dew point or 8% relative
humidity
Maximum to be 24°C (75.2°F) dew point or
90% relative humidity
Nonoperating
5% to 95%
38.7
°
C (101.7
°
F), maximum wet bulb
temperature
* All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per
1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C
per hour (36°F per hour). The upper limit and rate of change might be limited by the type and number of
options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m
(10,000 ft).
•
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise
website (
http://www.hpe.com/servers/ASHRAE
Mechanical specifications
Specification
Value
Height
4.29 cm (1.69 in)
Depth
60.70 cm (23.90 in)
Width
43.46 cm (17.11 in)
Weight (approximate range)
9.00 kg to 17.00 kg (19.82 lb to 37.44 lb)
Power supply specifications
Depending on the installed options and/or the regional location where the server was purchased, the
server is configured with one of the following power supplies:
•
HPE 550 W Power Supply (PN 730941-B21)
Summary of Contents for ProLiant DL60 Gen9
Page 5: ...Contents 5 Documentation feedback 111 Index 112 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 23: ...Illustrated parts catalog 23 ...
Page 33: ...Removal and replacement procedures 33 o Secondary PCI riser cage o PCI blank ...
Page 95: ...Component identification 95 Fan locations ...
Page 110: ...Acronyms and abbreviations 110 UID unit identification USB universal serial bus ...