Software and configuration utilities 106
10.
Press the
Esc
key to exit RBSU.
11.
Press the
F10
key to confirm exiting RBSU. The server automatically reboots.
Utilities and features
Array Configuration Utility
ACU is a utility with the following features:
•
Runs as a local application or remote service accessed through the HP System Management Homepage
•
Supports online array capacity expansion, logical drive extension, assignment of online spares, and
RAID or stripe size migration
•
Suggests the optimum configuration for an unconfigured system
•
For supported controllers, provides access to licensed features, including:
o
Moving and deleting individual logical volumes
o
Advanced Capacity Expansion (SATA to SAS and SAS to SATA)
o
Offline Split Mirror
o
RAID 6 and RAID 60
o
RAID 1 (ADM) and RAID 10 (ADM)
o
HP Drive Erase
o
Video-On-Demand Advanced Controller Settings
•
Provides different operating modes, enabling faster configuration or greater control over the
configuration options
•
Remains available any time that the server is on
•
Displays on-screen tips for individual steps of a configuration procedure
•
Provides context-sensitive searchable help content
•
Provides diagnostic and SmartSSD Wear Gauge functionality on the Diagnostics tab
ACU is now available as an embedded utility, starting with HP ProLiant Gen8 servers. To access ACU, use
one of the following methods:
•
If an optional controller is not installed, press
F10
during boot.
•
If an optional controller is installed, when the system recognizes the controller during POST, press
F5
.
For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers
running Microsoft® operating systems require one of the following supported browsers:
•
Internet Explorer 6.0 or later
•
Mozilla Firefox 2.0 or later
For Linux servers, see the README.TXT file for additional browser and support information.
For more information about the controller and its features, see the
HP Smart Array Controllers for HP ProLiant
Servers User Guide
on the HP website (
http://www.hp.com/support/SAC_UG_ProLiantServers_en
). To
configure arrays, see the
Configuring Arrays on HP Smart Array Controllers Reference Guide
on the HP
website (
http://www.hp.com/support/CASAC_RG_en
).
Summary of Contents for ProLiant DL385p Gen8
Page 6: ...Contents 6 Documentation feedback 132 Index 133 ...
Page 65: ...Hardware options installation 65 o 8 or 16 drive SFF o 8 drive LFF ...
Page 91: ...Cabling 91 LFF hard drive cabling Optical drive cabling ...
Page 92: ...Cabling 92 FBWC cabling 8 or 16 drive SFF 8 drive LFF ...
Page 127: ...Support and other resources 127 ...
Page 128: ...Support and other resources 128 ...