System Setup and Configuration for Red Hat Linux 7.3 Professional
Installing Management Agents for Servers for Linux
For instructions on installing and running Agents for Servers for Linux, refer to
the documentation located at
www.compaq.com/support/files/server/us/WebDoc/550/Linux.pdf
Configuring the Shared Storage
To configure the shared storage:
1.
Power on one server and boot from the SmartStart 6.1 (or later) CD.
2.
After booting with the SmartStart CD, click the
Maintenance
tab, then select and
run the
Array Configuration Utility.
3.
From the
Array Configuration Utility Configuration
screen, select the
Smart
Array Cluster Controller
to configure the shared storage hard drives. Refer to
the
HP Array Configuration Utility User Guide
on the documentation CD for
detailed information.
4.
Reboot the server and log in.
5.
Format and mount the shared storage disks.
NOTE:
No action is required on the second server at this time.
7-6
HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide
HP CONFIDENTIAL
Codename: Sopwith Part Number: 252621-002 Last Saved On: 11/8/02 3:06 PM