![HP ProLiant DL320 Generation 3 Maintenance And Service Manual Download Page 63](http://html.mh-extra.com/html/hp/proliant-dl320-generation-3/proliant-dl320-generation-3_maintenance-and-service-manual_164685063.webp)
Specifications
5-2
HP ProLiant DL320 Generation 3 Server Maintenance and Service Guide
System Unit
Table 5-1: System Unit Specifications
Item Description
Height
4.32 cm (1.70 in)
Depth
60.96 cm (24 in)
Width
42.62 cm (16.78 in)
Weight (maximum)
12.27 Kg (27 lbs)
Weight (no drives installed)
10.91 Kg (24 lbs)
U.S. and international input voltage requirements
Rated input voltage
100 VAC to 240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
6.0 A (110 VAC) / 3.0 A (220 VAC)
Rated input power
580 W
BTUs per hour
1990
Rated steady-state power
350 W
Temperature range
1
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-40
°
C to 70
°
C (-40
°
F to 158
°
F)
Relative humidity (non-condensing)
2
Operating
10 % to 90 %
Non-operating
5 % to 95 %
Maximum wet-bulb temperature
28
°
C (82.4
°
F)
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per
1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
2
Storage maximum humidity of 95 percent based on maximum temperature of 45
°
C (113
°
F).
Altitude minimum for storage is 70 KPa.
Power Supply
Table 5-2: Power Supply Specifications
Item Description
Input characteristics
Rated input voltage
100 VAC to 240 VAC
Rated input line
110 VAC / 220 VAC
Frequency range
50 to 60 Hz
continued