Setup 21
Two types of interconnect modules are available for HP BladeSystem c-Class enclosures: Pass-Thru modules
and switch modules. For more information about interconnect module options, see the HP website
IMPORTANT:
To connect to a network with a Pass-Thru module, always connect the Pass-Thru
module to a network device that supports Gigabit or 10 Gb speed, depending on the
corresponding Pass-Thru model.
Installing a server blade
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server blade
enclosure unless all bays are populated with either a component or a blank.
For the best possible HP BladeSystem and Virtual Connect experience and to prevent a future reboot, HP
requires updating the Onboard Administrator and Virtual Connect to the correct version before installing an
HP ProLiant Gen8 server blade. The version information is located on the tag on the front of the server blade.
For more information on this and other specific firmware and driver requirements as well as the latest
firmware and driver versions, download the SPP on the HP website
Remove the device bay blank.
Summary of Contents for ProLiant BL460c Gen8