12
ProCurve Switch vl Modules
Installing the Modules
Verifying the Module is Installed Correctly
Observe the Module Status LED for the slot in which the module is being
installed, and the Self Test and Fault LEDs on the switch to verify the module
is installed properly.
Figure 9. Checking LEDs for correct installation
When the module is installed properly and the switch is powered on, or the
module is installed when the switch already has power, the module undergoes
a self test that takes a few seconds. You can use the LEDs to determine that
the module is installed properly and has passed the self test, as described in
the “LED Behavior” table below.
LED Behavior
Power
Status
Modules
LED Mode
Fan
FDx
Act
1
2
A B
!
Use
vl Modules
only
ProCurve
Switch 4202vl
J8772A
Clear
Reset
Console
Auxiliary Port
Self Test
11
9
7
5
3
1
Link
Mode
12
6
4
2
Link
Mode
10
8
1
Link
1
Link
35
33
31
29
27
25
Link
Mode
36
30
28
26
Link
Mode
34
32
3
Link
3
Link
59
57
55
53
51
49
Link
Mode
6
Link
10/100Base-TX Ports (1-72) all ports
Spd
Power
Fault
Spd mode:
off = 10 Mbps
flash = 100 Mbps
on = 1000 Mbps
ProCur ve
10/100-TX
vl Module
J8765A
vl
Module
13
15
11
9
7
5
3
1
17
19
21
23
Link
Mode
Link
Mode
14
16
12
10
8
6
4
2
18
20
22
24
Link
Mode
Link
Mode
10/100Base-TX Ports — all ports are HP A uto MDI- X
A
Module Link and Mode
LEDs
Module Status LEDs
Self Test LED
Fault LED
LED
Display for a Properly Installed Module
Module Status
(for the slot in which you are installing the module) The LED goes
ON as soon as the module is installed and the switch is powered on,
and stays ON steadily.
Self Test
ON briefly while the module is being tested, then OFF.
Note:
If the switch was powered off while the module was installed,
when the switch is powered on, the Self Test LED will stay ON for
the duration of the whole switch self test.
Fault
OFF
Link and Mode (on
the modules)
For a module that is installed when the switch is already powered
on (hot swap), all the Link and Mode LEDs on the module go ON for
approximately 3 to 10 seconds, then OFF for 5 to 10 seconds
depending on the module.
If the module is already installed when the switch is powered on or
reset, the process described above occurs approximately 30
seconds after the power on or reset, during which time the switch
is being tested.
Summary of Contents for ProCurve J8766A
Page 2: ......
Page 3: ...ProCurve Switch vl Modules Installation Guide ...