![HP ProCurve 1600M Management And Configuration Manual Download Page 622](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_management-and-configuration-manual_155305622.webp)
Troubleshooting
Debug and Syslog Messaging Operation
Debug Destinations
Debug enables you to disable and re-enable Syslog messaging to configured
servers, and to designate a CLI session to receive messaging of any debug type.
Syntax:
[no] debug destination < logging | session >
logging
This command enables Syslog logging to the configured
Syslog server(s). That is, the switch sends the debug mes
sage types (specified by the
debug <
debug-type
>
command
in the preceding section) to the configured Syslog server(s).
(Default: Logging disabled)
(To configure a Syslog server IP address, refer to “Syslog
Operation” on page C-39.)
Note:
Debug messages from the switches covered in this
guide carry a “debug” severity level. Because some Syslog
servers, in their default configuration, ignore Syslog mes
sages with this severity level, you should ensure that the
Syslog servers you intend to receive debug messages are
configured to accept the “debug” severity level. For more
information, refer to
“Operating Notes for Debug and Sys
.
session
Enables or disables transmission of event notification mes
sages to the CLI session that most recently executed this
command. The session can be on any one terminal emula
tion device with serial, Telnet, or SSH access to the CLI at
the Manager level prompt (
ProCurve#_
). If more than one
terminal device has a console session with the CLI, you can
redirect the destination from the current device to another
device. Do so by executing
debug destination session
in the
CLI on the terminal device on which you now want to
display event messages.
Event message types received on the selected CLI session are
those specified by the
debug <
debug-type
>
command. (Refer
.)
C-38
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......