Redundancy (Switch 8212zl)
Hotswapping Management Modules
When the Standby Module is not Available
If you have disabled redundancy with the configuration level command
no
redundancy management-module
, or the standby module failed selftest, the
Dwn
LED will not turn green to indicate it is OK to hotswap out the active
management module.
N o t e
If you remove the active management module without pressing the
MM
Shutdown
button, any files that may have been in the process of
synchronizing will not finish synchronizing to the standby module and all file
transfer is aborted.
Hotswapping In a Management Module
If another management module is hotswapped in while there is an active
management module booted up, the newly hotswapped management module
becomes the standby module. It partially boots up and heartbeats are sent
back and forth with the active management module. No negotiating is needed
as to which module will become the active management module as there is
already a functioning active management module. However, these conditions
must be met to determine if the hotswapped module can become a standby
management module:
■
The hotswapped module must pass selftest
■
Redundancy is not administratively disabled (using the configuration
level command
no redundancy management-module
). If the active manage
ment module’s config file has redundancy administratively disabled, the
hotswapped management module goes into “offline” mode.
Software Version Mismatch Between Active
and Hotswapped Module
Sometimes the software version in the hotswapped module may not match
the software version in the active module. In these cases the following occurs:
1. The active module sends the primary and secondary images in flash to the
hotswapped module.
2. The module that was hotswapped in then reboots if necessary to primary
or secondary flash, whichever matches (if it doesn’t match already).
3. After the hotswapped management module finishes booting, it is sent the
config and other critical files from the active management module.
15-16
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......