![HP ProCurve 1600M Management And Configuration Manual Download Page 266](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_management-and-configuration-manual_155305266.webp)
Power Over Ethernet (PoE) Operation
Configuring PoE Operation
Configuring PoE Operation
In the default configuration, PoE support is enabled on the Gig-T ports in a
PoE module installed on the switch. The default priority for all ports is
Low
and the default power notification threshold is
80
(%). Using the CLI, you can:
■
Change the PoE priority level on individual PoE ports
■
Disable or re-enable PoE operation on individual PoE ports
■
Change the threshold for generating a power level notice
Changing the PoE Port Priority Level
Syntax:
interface <
port-list
> power [ critical | high | low ]
Reconfigures the PoE priority level on
<
port-list
>.
For a given level,
ports are prioritized by port number in ascending order. For
example, if ports A1-A24 have a priority level of critical, port A1
has priority over ports A2-A24.
If there is not enough power available to provision all active PoE
ports at a given priority level, then the lowest-numbered port at that
level will be provisioned first, starting with module A, then B, C,
and so on. PoE priorities are invoked only when all active PoE ports
cannot be provisioned (supplied with PoE power).
•
Critical:
Specifies the highest-priority PoE support for
<
port-list
>
.
The active PoE ports at this level are provisioned
before the PoE ports at any other level are provisioned.
•
High
:
Specifies the second priority PoE support for
<
port-list
>
.
The active PoE ports at this level are provisioned
before the Low priority PoE ports are provisioned.
•
Low
(the default): Specifies the third priority PoE support for
<
port-list
>.
The active PoE ports at this level are provisioned only
if there is power available after provisioning any active PoE
ports at the higher priority levels.
You can use one command to set the same priority level on PoE
ports in multiple modules. For example, to configure the priority
to
High
for ports c5-c10, C23-C24, D1-D10, and D12, you could use
this command:
ProCurve(config)# interface c5-c10,c23-c24,d1-
d10,d12 power high
11-14
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......