![HP ProCurve 1600M Management And Configuration Manual Download Page 248](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_management-and-configuration-manual_155305248.webp)
Port Status and Configuration
Uni-Directional Link Detection (UDLD)
N o t e s
■
You must configure the same VLANs that will be used for UDLD on
all devices across the network; otherwise, the UDLD link cannot be
maintained.
■
If a VLAN ID is not specified, then UDLD control packets are sent out
of the port as untagged packets.
■
To re-assign a VLAN ID, re-enter the command with the new VLAN ID
number. The new command will overwrite the previous command
setting.
■
When configuring UDLD for tagged ports, you may receive a warning
message if there are any inconsistencies with the port’s VLAN config
uration (see page 31 for potential problems).
Viewing UDLD Information
The following show commands allow you to display UDLD configuration and
status via the CLI.
Syntax:
show link-keepalive
Displays all the ports that are enabled for link-keepalive.
Syntax:
show link-keepalive statistics
Displays detailed statistics for the UDLD-enabled ports on the
switch.
Syntax:
clear link-keepalive statistics
Clears UDLD statistics. This command clears the packets sent,
packets received, and transitions counters in the show link
keepalive statistics display.
10-28
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......