Port Status and Configuration
Uni-Directional Link Detection (UDLD)
N o t e
When at least one port is UDLD-enabled, the switch will forward out UDLD
packets that arrive on non-UDLD-configured ports out of all other non-UDLD
configured ports in the same vlan. That is, UDLD control packets will “pass
through” a port that is not configured for UDLD. However, UDLD packets will
be dropped on any blocked ports that are not configured for UDLD.
Changing the Keepalive Interval
By default, ports enabled for UDLD send a link health-check packet once every
5 seconds. You can change the interval to a value from 10 – 100 deciseconds,
where 10 is 1 second, 11 is 1.1 seconds, and so on. For example, to change
the packet interval to seven seconds, enter the following command at the
global configuration level:
ProCurve(config)# link-keepalive interval 70
Changing the Keepalive Retries
By default, a port waits five seconds to receive a health-check reply packet
from the port at the other end of the link. If the port does not receive a reply,
the port tries four more times by sending up to four more health-check
packets. If the port still does not receive a reply after the maximum number
of retries, the port goes down.
You can change the maximum number of keepalive attempts to a value from
3 – 10. For example, to change the maximum number of attempts to 4, enter
the following command at the global configuration level:
ProCurve(config)# link-keepalive retries 4
Configuring UDLD for Tagged Ports
The default implementation of UDLD sends the UDLD control packets
untagged, even across tagged ports. If an untagged UDLD packet is received
by a non-ProCurve switch, that switch may reject the packet. To avoid such
an occurrence, you can configure ports to send out UDLD control packets that
are tagged with a specified VLAN.
To enable ports to receive and send UDLD control packets tagged with a
specific VLAN ID, enter a command such as the following at the interface
configuration level:
ProCurve(config)#interface l link-keepalive vlan 22
10-27
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......