Port Status and Configuration
Uni-Directional Link Detection (UDLD)
The following commands allow you to configure UDLD via the CLI.
Syntax:
[no] interface <
port-list
> link-keepalive
Enables UDLD on a port or range of ports.
To disable the feature, enter the
no
form of the command.
Default: UDLD disabled
Syntax:
link-keepalive interval <
interval
>
Determines the time interval to send UDLD control packets. The
<interval> parameter specifies how often the ports send a UDLD
packet. You can specify from 10 – 100, in 100 ms increments,
where 10 is 1 second, 11 is 1.1 seconds, and so on.
Default: 50 (5 seconds)
Syntax:
link-keepalive retries <
num
>
Determines the maximum number of retries to send UDLD
control packets. The <num> parameter specifies the maximum
number of times the port will try the health check. You can specify
a value from 3 – 10.
Default: 5
Syntax:
[no] interface <
port-list
> link-keepalive vlan <
vid
>
Assigns a VLAN ID to a UDLD-enabled port for sending of tagged
UDLD control packets.Under default settings, untagged UDLD
packets can still be transmitted and received on tagged only
ports—however, a warning message will be logged.
The
no
form of the command disables UDLD on the specified
port(s).
Default: UDLD packets are untagged; tagged only ports will
transmit and receive untagged UDLD control packets
Enabling UDLD
UDLD is enabled on a per port basis. For example, to enable UDLD on port
a1, enter:
ProCurve(config)#interface al link-keepalive
To enable the feature on a trunk group, enter the appropriate port range. For
example:
ProCurve(config)#interface al-a4 link-keepalive
10-26
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......