Event Messages
HP NonStop TMF Management Programming Manual—540140-008
6-135
Descriptions of Event Messages
151: ZTMF-EVT-WrongGlobInfoFileVer
The specified configuration file has a version number that is not consistent with the
version number of the installed TMF software.
Additional Unconditional Tokens
ZTMF-TKN-EVTHDR-ProcessType
is the subject token of the event message, and it identifies the TMF process that
generated the event. The value of this token for this event is ZTMF-VAL-
PROC-TMP.
ZTMF-TKN-FileName
contains the name of the configuration file.
ZEMS-TKN-Emphasis
is set to True for this event.
Effect
TMF crashes.
Recommended Action
Contact your service provider and provide all relevant information as follows:
Descriptions of the problem and accompanying symptoms
Details from the message(s) generated
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and a CPU dump, if applicable
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), supply your system number and the numbers and versions of all
related products as well.
Additional Unconditional Tokens
ZTMF-TKN-EVTHDR-ProcessType token-type ZSPI-TYP-Enum.
ZTMF-TKN-FileName token-type ZSPI-TYP-FName.
ZEMS-TKN-Emphasis token-type ZSPI-TYP-Boolean.
Event-Message Text
Configuration file ZTMF-TKN-FileName has the wrong version
number.
Summary of Contents for NonStop TMF