System LEDs and Switches
C-16
HP ProLiant ML530 Generation 2 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: l-appc System LEDs and Switches.doc
Codename: Seattle Slew Part Number: 225579-002 Last Saved On: 1/8/03 3:23 PM
Table C-11: Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED
Online
LED
Fault
LED
State
On Off Off
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is being accessed and is not configured as part of an
array.
On Flashing
Off
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is rebuilding or undergoing capacity expansion.
Flashing Flashing Flashing
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off
Off
Off
OK to replace the drive online if a predictive failure alert is
received and the drive is attached to an array controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, a powered-on controller is not
accessing the drive.
-Or-
The drive is configured as an online spare.
continued