
Installing Hardware Options
3-54
HP ProLiant ML530 Generation 2 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: d-ch3 Installing Hardware Options.doc
Codename: Seattle Slew Part Number: 225579-002 Last Saved On: 1/8/03 3:00 PM
Drive Bays
ProLiant ML530 Generation 2 servers support installation of the following storage
devices into a drive bay:
•
Hot-plug hard drives
•
Hot-plug universal tape drives
Installing a Hot-Plug Hard Drive into a Drive Bay
Installation of optional hot-plug hard drives requires the following operations:
•
Determining the proper hot-plug hard drive installation order
•
Following the guidelines for installing SCSI devices
•
Installing the hot-plug hard drive
CAUTION:
Always populate drive bays with either a hard drive or blank. Proper
airflow can only be maintained when the bays are populated. Unpopulated drive bays
can lead to improper cooling and thermal damage.