* Location of the network and electrical connections
The height of the room should be at least 2500 mm (99 in).
The build unit measures 652 × 760 × 1050 mm.
Environmental specifications
Temperature during installation
20–30°C (68–86°F)
Operating temperature
20–30°C (68–86°F)
Recommended operating temperature for best performance
20–30°C (68–86°F)
Storage and reshipping temperature
−25 to +55°C (−13 to +131°F)
Operating humidity
30–70% without condensation
Storage humidity
< 90% without condensation
Maximum altitude when printing
3,000 m or 9,842.6 ft. (2,000 m or 6,561.8 ft. for China)
Notes
●
The customer must ensure that the room in which the system is installed meets environmental, ventilation,
and air conditioning specifications. The operating conditions (temperature and humidity) should remain as
stable as possible within the specified limits.
To ensure that environmental conditions are always met, a measuring system should be implemented. A
room-temperature and relative-humidity sensor with data logger should be used to take measurements
during installation and first builds.
●
The printer, build unit, and processing station should be kept at operating conditions if they contain
material.
●
The printer, build unit, and processing station should be kept indoors.