1-9
Introducing the ProCurve Switch 5300xl Series
Back of the Switch
In
tr
o
d
u
c
ing t
he P
roC
ur
ve
Switch 5300xl S
e
ries
Back of the Switch
.
Figure 1-8. Example back of 5300xl Series
Power Connector
The Switch 5300xl Series do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.
Slot for Redundant Power Supply
A second, load-sharing redundant power supply (ProCurve Switch gl/xl RPS,
J4839A) can be installed in the back of the Switch 5300xl Series. To provide
true redundancy, this second power supply should be connected to a different
AC power source from the other supply. Then, if one AC power source fails,
the switch will continue to run.
C a u t i o n
The switch redundant power supply
is
hot swappable, but, as indicated by the
caution statement on the power supply, it
must
be disconnected from AC
power before being installed or removed.
Because the switch can run on a single supply, removing a redundant supply
will not interrupt switch operation.
AC power connector
slot for installing optional
redundant power supply
pull strap
Caution:
.
Refer to the installation guide for proper power cord selection.
.
Disconnect AC power from this power supply BEFORE installing or removing
the supply. Otherwise, damage to the equipment may result.
Summary of Contents for J4819A
Page 2: ...stingray book Page 12 Sunday November 2 2003 9 38 AM ...
Page 3: ...ProCurve Switch 5300xl Series Installation and Getting Started Guide ...
Page 20: ......
Page 46: ......
Page 74: ......
Page 105: ......
Page 106: ......
Page 107: ...stingray book Page 12 Sunday November 2 2003 9 38 AM ...