WARNING:
The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline
battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the
risk of personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
• Replace only with the spare designated for this product.
Procedure
1.
Power off the server and remove it from the enclosure (
Preparing the server blade for servicing
page 112).
2.
Remove the access panel (
on page 117).
3.
Remove the battery.
To replace the component, reverse the removal procedure.
Mezzanine cards
The I/O subsystem is composed of embedded core I/O and up to three mezzanine cards. The server
blade supports the following configurations:
• Up to three type I mezzanine cards using up to x8-PCIe Gen-2 links
• One type I and up to two type II mezzanine cards using up to x8-PCIe Gen-2 links
The server blade does not support PCI Hot Plug.
Procedure
1.
Power off the server and remove it from the enclosure (
Preparing the server blade for servicing
page 112).
2.
Remove the access panel (
on page 117).
3.
Remove the mezzanine card.
Mezzanine cards
127
Summary of Contents for Integrity BL860c i4
Page 7: ...W 163 Contents 7 ...