![HP Indigo Press WS4000 Service Manual Download Page 77](http://html.mh-extra.com/html/hp/indigo-press-ws4000/indigo-press-ws4000_service-manual_163659077.webp)
HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 77 of 221
Figure 73 Inverters installed on electric cabinet
•19. Install the inverters on the electric cabinet door.
a. Measure four holes down on the cabinet door from the cable channel
in the middle of the door.
b. Place the inverter plate in position, and leave any existing screws on
the door in place.
c. Install the inverter plate with the two inverter units on the electric
cabinet door with three screws on the right side of the door and three
screws on the left side of the door.
d. Run the wires from the inverters to the electric cabinet through the wire
channels on the door and in the electric cabinet.
•20. Run the two orange cables (labeled VBI, upper and VBFU, lower) from the
inverter to the blower connector boxes.