![HP Indigo Press WS4000 Service Manual Download Page 73](http://html.mh-extra.com/html/hp/indigo-press-ws4000/indigo-press-ws4000_service-manual_163659073.webp)
HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 73 of 221
Figure 68 Blower wiring
b. Disconnect and discard the cables to the blowers.
Note:
The order of connecting the wires to the terminals determines the phase. If the
same order is not maintained, the fan may blow in the reverse direction.
•8. Disconnect the 22Q3 wires (CC203 cable) from the L1, L2, L3 positions.
These wires will be connected to the new 22Q3 switches.
Note:
The wires are labeled with their insert points.
•9. Disconnect the 22Q5 wires (CC204 cable) from the L1, L2, L3 positions.
These wires will be connected to the new 22Q5 switches.
•10. Disconnect the violet wire from the 14 slot in the 22Q3 switch, and follow it
back to the 60A0 pin 1 position on the bottom of the power supply.
Remove the violet wire.