Figure 171 Installing motor on Output assembly wall
f.
Install the motor with the connectors facing down through the motor
plate, NIP drive belt, the Input section drive belt and the hole in the
press wall.
g. Insert the screws in the four holes on the motor base.
h. Connect the encoder and the power cables to the Nip motor.
i.
Use the sonic meter to test the belt tension.
Replacing the FP motor belt
The following procedure describes replacing the Input section drive belt on the Feed
III gear: