Chiller timer 267
For additional support, please contact your HP Indigo service center.
Chiller timer
When the time required by the chiller to reach working temperature hinders productivity,
you can turn the chiller on before the start of the shift. Use the chiller timer to turn the
chiller on before the press is turned on.
If the press enters the Ready state after being turned on, bypass the chiller timer. Chiller
bypass is the default timer state.
You can set the chiller timer to three On/Off functions per day. Setting the timer On turns
on the chiller independently of the press status. The press command of the chiller
overrides the chiller timer command.
Set the timer to On about 30 minutes before the start of a shift. Set the timer to Off 30
minutes after the start of a shift. This ensures that the chiller is turned off only at the end
of the workday.
The chiller timer is located behind the electronics cabinet, below the Main Power switch.
Default
Cause
Solution
Restart procedure
The control thermostat
displays the following
codes:
LO
The temperature has
been below the setpoint
for some minutes
If the compressor is
stopped, the water
temperature will rise to
normal eventually. If the
compressor is still
running, contact your
HP Indigo service
center.
The chiller is still
working normally
HI
The temperature has
been above the
setpoint for some
minutes
Check that the cold
water setpoint is within
the limits indicated (see
‘Operating conditions’
on page 263).
The chiller is still
working normally
E0, Er2, EE
The thermostat or
temperature sensor is
faulty
Contact your HP Indigo
service center.
The chiller can be
restarted when the
faulty part is replaced.
Figure 19-3. Chiller timer location
Electronics
cabinet, door
open
Chiller timer
Electronics
cabinet, door
closed
Summary of Contents for Indigo press 3050
Page 1: ...HP Indigo press 3050 User guide English version ...
Page 2: ...hp indigo press 3050 user guide ...
Page 13: ...12 Chapter 1 Preface ENWW ...
Page 23: ...22 Chapter 2 Getting started ENWW ...
Page 41: ...40 Chapter 4 HP Indigo press 3050 basics ENWW Figure 4 5 Related topics ...
Page 53: ...52 Chapter 5 The main windows ENWW ...
Page 83: ...82 Chapter 6 Operating the press ENWW ...
Page 91: ...90 Chapter 7 Operator routines ENWW Figure 7 7 Inner front wall O O O O ...
Page 99: ...98 Chapter 7 Operator routines ENWW ...
Page 136: ...ENWW 135 10PIP This chapter contains the following sections z Overview z Replacing the PIP ...
Page 189: ...188 Chapter 11 Paper transport ENWW ...
Page 219: ...218 Chapter 15 Scorotron ENWW ...
Page 257: ...256 Chapter 17 Pre transfer erase PTE ENWW ...
Page 271: ...270 Chapter 19 Chiller ENWW ...