Cluster Interconnect Link Ports LEDs
The controller node has two Cluster Interconnect Link ports and each includes two LEDs.
NOTE:
•
4-node systems
—Cluster Interconnect Link ports are used to connect nodes together.
•
2-node system
—Cluster Interconnect Link ports are
not
used and LEDs should always be
off.
Figure 8 Cluster Interconnect Link ports LEDs location
Table 7 Node Cluster Interconnect Link ports LEDs description
Indicates
State
Appearance
LED Function
Fault—No link established
On
Amber
Fault
1
1. Interconnect link cabling error
Flashing
2. Controller node in wrong slot
3. Serial number mismatch between controller nodes
No fault
Off
Link established
On
Green
Status
2
No link established
Off
LED Troubleshooting
•
Incorrectly configured interconnect link cables result in the port amber LED being on.
•
Flashing amber LEDs can be caused by any of the following:
Cluster link cabling error
◦
◦
Controller node in wrong slot
◦
Serial number mismatch between controller nodes