2. Turn on PCS mode if necessary (Optional).
This step does not need to be performed if the Test Set was configured for PCS
mode when last powered down. This step is only applicable to Test Sets with the
HP 83236 PCS Interface and firmware later than A.05.00. The PCS Interface must
be installed according to instructions found in the HP 83236B PCS Interface
Operating Manual.
HP-IB Syntax:
"CONF:PCSM ‘On’" !turns PCS mode on
Manual Operation:
1. Press then release the SHIFT key then press the
TESTS key to display the CONFIGURE
screen.
2. Position the cursor at the PCS Mode field.
3. Press the knob to underline “On”.
4. Cycle power to the Test Set to initialize
communication between the Test Set and PCS
Interface.
5. Preset the Test Set.
CONFIGURE
RF In/Out
- 2.0
RF Level
Offset
On/Off
The PCS Interface extends the measurement capability of the HP 8924C to include the PCS frequency range.
The Test Set, when installed with firmware revision A.05.00 or higher, controls the PCS Interface via the rear-
panel serial AUX CONTROL interface. A rocker switch on the PCS Interface rear panel labeled “HP-IB/Ser”
must be in the “Ser” position for serial control.
When switching between the cellular and PCS frequency bands it is not necessary to turn PCS Mode “Off”.
This is because the PCS Interface provides conversion bypass paths (bypassing frequency up-conversion on
the generator path and frequency down-conversion on the analyzer path) for operation in the cellular band.
PCS Mode
On/Off