![HP HP 8924C Application Manual Download Page 144](http://html.mh-extra.com/html/hp/hp-8924c/hp-8924c_application-manual_166201144.webp)
144
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amtxtst.fb
Chapter 4, CDMA Transmitter Tests
Measuring Waveform Quality
3. Set the test parameter Î
or
.
HP-IB Syntax
"CDMA:CELL:ASEC -75" ! Sets the Sector A power field to -75 dBm/BW
Manual Operation:
1. Position the cursor at the Sector A Power field.
2. Set the value with the DATA keys. Refer to the
TIA/EIA IS-98 performance standards for test
parameters.
3. Press the ENTER key or the knob to enter the
value.
The value for Sector A Power is referred to as I
or
..
AWGN
Off
Sector A
Power
-75.0
dBm/BW
Sector B
Power
Off
Traffic
To Screen
CDMA GENERATOR CONTROL
-7.4
OCNS
-1.4371
----
RF Power
PN Offset
12
CDMA
CDMA GEN
Analog
RX TEST
Cnfig
PRNT CNFG
17
dB
dB
Eb/Nt
8
Paging
-16.0
dB
1
Sync
-16.0
dB
1
Pilot
-7.0
dB
0
Walsh
Traffic
-16.0
OCNS
-1.1435
PN Offset
36
42
dB
dB
12