![HP HP 8924C Application Manual Download Page 111](http://html.mh-extra.com/html/hp/hp-8924c/hp-8924c_application-manual_166201111.webp)
111
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amrcvrt.fb
Chapter 3, CDMA Receiver Tests
Measuring Single Tone Desensitization
Cha
p
te
r 3
C
D
M
A
R
ece
iver
Test
s
Signal Generator.
5.
"Set the test parameter Traffic Ec/Ior." on page 120
Screen: CDMA CELLULAR MOBILE RECEIVER TEST
Enter value in:
Traffic
.
6.
"Set the test parameter Îor ." on page 121
.
Screen: CDMA CELLULAR MOBILE RECEIVER TEST
Enter value in:
Sector A Power
7.
"Set the FER specification." on page 122
Screen: CDMA CELLULAR MOBILE RECEIVER TEST
Enter value in:
FER Specs
8.
"Set the data rate." on page 123
Screen: CDMA CELLULAR MOBILE RECEIVER TEST
Enter value in:
Data Rate
9.
"Set up display to show interim results (Optional)." on page 108
Screen: CDMA CELLULAR MOBILE RECEIVER TEST
Start measurement in -
Display Interim Results
10.
"Arm a single measurement." on page 109
.
Screen: CDMA CELLULAR MOBILE RECEIVER TEST
Start measurement in:
Meas Cntl
,
Arm
11.
"Monitor the annunciators to determine test status." on page 110
Screen: CDMA CELLULAR MOBILE RECEIVER TEST
Observe:
Passed
,
Failed
, or
Max Frames
Programming Example
The following programming example illustrates the IS-98 recommended
procedure for measuring Single Tone Desensitization.
10 ! RE-STORE "c:\hpbasic\setrain\single_tone"
20 ! This program measures Single Tone Desensitization
26 Test=1
27 Loss=1.5 !Path loss
30 OUTPUT 714;"*CLS"
40 CLEAR SCREEN
50 CLEAR 714
60 OUTPUT 714;"CDMA:CALL:END"
70 WAIT 1