129
To do…
Use the command…
Remarks
Stop running the specified patches
patch deactive
patch-number
slot
slot-number
Required
When you stop running a patch,
the patch state becomes
DEACTIVE, and the system runs in
the way before it is installed with
the patch.
Delete the specified patches from
the memory patch area
patch delete
patch-number
slot
slot-number
Required
Deleting patches only removes the
patches from the memory patch
area, and does not delete them
from the storage medium. The
patches turn to IDLE state after this
operation. After a patch is deleted,
the system runs in the way before it
is installed with the patch.
Displaying and maintaining the software upgrade
To do…
Use the command…
Remarks
Display information about the boot
file
display boot-loader
[
slot
slot-number
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
Available in any view
Display the patch information
display patch information
[
|
{
begin
|
exclude
|
include
}
regular-expression
]
Available in any view
Software upgrade configuration examples
Unless otherwise noted, devices in the configuration examples are operating in non-FIPS mode.
Immediate upgrade configuration example
Network requirement
•
As shown in
, the IRF virtual device comprises two member devices, the master with the
member ID of 1 and the slave switch with the member ID of 2.
•
The current software version is
soft-version1
for the IRF virtual device. Upgrade the software version
of the IRF virtual device to
soft-version2
and configuration file to
new-config
.
•
The latest application
soft-version2.bin
and the latest configuration file
new-config.cfg
are both
saved on the TFTP server.
•
The IP address of the IRF virtual device is 1.1.1.1/24, the IP address of the TFTP server is 2.2.2.2/24,