background image

 

 

About this Manual 

 
We’ve added this manual to the Agilent website in an effort to help you support 
your product.  This manual is the best copy we could find; it may be incomplete 
or contain dated information.  If we find a more recent copy in the future, we will 
add it to the Agilent website. 
 
 

Support for Your Product 

 
Agilent no longer sells or supports this product.  Our service centers may be able 
to perform calibration if no repair parts are needed, but no other support from 
Agilent is available.  You will find any other available product information on the 
Agilent Test & Measurement website, 

www.tm.agilent.com

.

 

 
 
 

HP References in this Manual 
 

This manual may contain references to HP or Hewlett-Packard.  Please note that 
Hewlett-Packard's former test and measurement, semiconductor products and 
chemical analysis businesses are now part of Agilent Technologies.  We have 
made no changes to this manual copy.  In other documentation, to reduce 
potential confusion, the only change to product numbers and names has been in 
the company name prefix: where a product number/name was HP XXXX the 
current name/number is now Agilent XXXX.  For example, model number 
HP8648A is now model number Agilent 8648A. 
 
 

 

Summary of Contents for HP 16500B

Page 1: ...ble You will find any other available product information on the Agilent Test Measurement website www tm agilent com HP References in this Manual This manual may contain references to HP or Hewlett Packard Please note that Hewlett Packard s former test and measurement semiconductor products and chemical analysis businesses are now part of Agilent Technologies We have made no changes to this manual...

Page 2: ...cation number 16500 97012 First edition April 1995 For Safety information Warranties and Regulatory information see the pages behind the index Copyright Hewlett Packard Company 1993 1994 1995 All Rights Reserved HP 16500H Interface Module ...

Page 3: ...s chapter tells you where to find information on troubleshooting the system depending on which environment you are using the HP 16500B system in See Also The HP 16500H LAN Interface Module Administrator s and Service Guide for information on installing and setting up the HP 16500H in the LAN environment The HP 16500B Logic Analysis System Setting UP the System Guide for information on installing a...

Page 4: ...HP 16501A Expansion Frame Interface 2 7 HP 16505A Protoytype Analyzer 2 8 3 Servicing the Interface Module Verify the Interface Module Performance 3 2 Troubleshooting an HP 16501A Expansion Frame 3 7 Troubleshooting in an Ethernet LAN Environment 3 8 Troubleshooting in the HP 16505A Prototype Analyzer Environment 3 9 Removing and Replacing the HP 16500H Interface Module 3 10 Returning Parts 3 13 O...

Page 5: ...Contents 2 ...

Page 6: ...1 Introducing the HP 16500H 1 2 Accessories Supplied 1 3 Requirements 1 3 Physical Connections 1 3 LAN Support 1 4 Introducing the HP 16500H Interface Module ...

Page 7: ...alysis System connection to an Ethernet 10Base T Local Area Network LAN connection to an HP 16501A Expansion Frame for the HP 16500B Logci Analysis System a high speed port for connecting the HP 16500B to an HP 16505A Prototype Analyzer The HP 16500H interface module Expander Frame connector Ethertwist LAN connector High speed port 1 2 ...

Page 8: ...these tools If your HP 16500H was not installed by HP you will receive these tools Requirements HP 16500B Logic Analysis System mainframe and one of the following NFS or FTP capabilities on your TCP IP Ethernet LAN or HP 16501A Expansion Frame or HP 16505A Prototype Analyzer Physical Connections RJ 45 connector for direct connection to 10Base T networks 68 pin D connector for connection to an HP 1...

Page 9: ...AN Support For information about the LAN protocols and file types supported by the HP 16500H refer to the LAN Administrator s and Service Guide Introducing the HP 16500H Interface Module LAN Support 1 4 ...

Page 10: ... 16500B in one of the three applications supported by the interface module refer to the documentation for the specific application This chapter provides references to those other documents To Install the HP 16500H Hardware 2 2 To Verify the Installation 2 4 Ethernet LAN Interface 2 5 HP 16501A Expansion Frame Interface 2 7 HP 16505A Prototype Analyzer Interface 2 8 Installing the Interface Module ...

Page 11: ...er supply has any illumination a significant charge remains on the capacitors C AU TI O N Use grounded wriststraps and mats when performing any service to this module or to the HP 16500B Logic Analysis System Electrostatic discharge can damage electronic components For correct orientation of the cables match the slots on the cable connectors and on the board connectors 1 Remove power from the HP 1...

Page 12: ...Connect the 80 pin cable to the CPU board and to the interface module Before installing the cable inspect the cable and the connectors for any signs of damage a Slide the 80 pin cable halfway through the rear slot of the card cage between the interface module and the CPU board b Connect the cable to the CPU board c Connect the cable to the interface module 6 Replace the top and bottom covers the o...

Page 13: ... tests are finished the screen displays the System Configuration menu If the operating system finds an interface module installed then Ethernet is available in the Communications menu 2 If Ethernet is not available in the Communications menu go to Verifying the Interface Module Performance in Chapter 3 of this manual Verifying the Installation Ethernet should be listed here Installing the Interfac...

Page 14: ...nit MAU is required 2 Set up the configuration menus on the HP 16500B mainframe You can configure the interface module to work with your network from the HP 16500B front panel touchscreen After the HP 16500B power up tests are complete the Ethernet configuration can be accessed in the Communications menu The interface module automatically obtains the subnet mask by sending a broadcast ICMP query o...

Page 15: ...y and determine where bottlenecks or other problems are occurring 4 Mount the HP 16500B system with an NFS mount An NFS mount of the 16500B system depends on the network environment the system is being mounted to For UNIX the mount command with the computer name and mount point are required In MS DOS a virtual drive specifier and 16500B IP address are required File Manager in MS Windows is used to...

Page 16: ...nfigured and utilized Detailed service information for the HP 16500B mainframe and 16501A Expansion frame is covered in the HP 16500B 16501A Service Manual The expansion frame is recognized by the mainframe if the Master Frame text on the left side of the mainframe power up screen appears as a blue user select field If the text does not appear as a blue field the most likely cause is a defective i...

Page 17: ... HP 16505A Protoytype Analyzer permits you to connect a Prototype Analyzer to the HP 16500B mainframe Detailed installation information is covered in the HP 16505A Prototype Analyzer Installation Guide Installing the Interface Module HP 16505A Protoytype Analyzer 2 8 ...

Page 18: ... 16501A Expansion Frame 3 7 Troubleshooting in an Ethernet LAN Environment 3 8 Troubleshooting in the HP 16505A Prototype Analyzer Environment 3 9 Removing and Replacing the HP 16500H Interface Module 3 10 Returning Parts 3 13 Ordering Replacable Parts 3 14 Replacable Parts 3 15 Servicing the Interface Module ...

Page 19: ...ection is tested depending on the LAN topology used Because EtherTwist 10Base T is used the interface module will listen for the heartbeat signal from the LAN If a heartbeat is received then the physical connection is considered good The second section is tested using internal loopback features of the LAN IC Transmitted packets are looped back to the receive circuit of the LAN IC When the looped b...

Page 20: ...Ensure that the cable is connected according to the installation procedures and that all cables are properly seated For installation procedures refer to chapter 2 Installing the Interface Module d Install the top cover of the HP 16500B mainframe connect the power cable and reapply power 2 Touch the blue field in the upper left corner of the HP 16500B screen Select System from the pop up menu 3 Tou...

Page 21: ... installation procedures and that all cables are properly seated For installation procedures refer to chapter 2 Installing the Interface Module d Install the top cover of the HP 16500B mainframe connect the power cable and reapply power If Ethernet still does not appear then suspect a defective CPU board Refer to the HP 16500B 16501A Service Guide for infomation on testing and replacing the CPU ba...

Page 22: ...oard Test then select Run If an HP 16501A expansion frame is not connected then expect a No Expansion Card Present message to appear when you run the Option Board Test Refer to the HP 16500B 16501A Service Guide for more information about the expansion frame Servicing the Interface Module Verify the Interface Module Performance 3 5 ...

Page 23: ...r ends Check that the LAN cable is good and that all signal lines in the cable have electrical integrity To replace a defective interface module refer to Removing and replacing the interface module later in this chapter 9 Exit the Test System a Touch the Module field then touch Test System b Touch the Menu field then touch Exit Test c Touch the field near the center of the screen to exit the test ...

Page 24: ...ctive use the procedures in this chapter to verify the interface module performance and if necessary replace the hardware The expnasion frame is recognized by the mainframe if the Master Frame text on the left side of the mainframe power up screen appears as a blue user select field If the text does not appear as a blue field the most likely cause is a defective interface module Servicing the Inte...

Page 25: ...N refer to the HP16500H LAN Administrator s and Service Guide If you suspect that the HP 16500H Interface Module is defective use the procedures in this chapter to verify the interface module performance and if necessary replace the hardware Servicing the Interface Module Troubleshooting in an Ethernet LAN Environment 3 8 ...

Page 26: ...pe Analyzer refer to the HP16505A Prototype Analyzer Service Guide If you suspect that the HP 16500H Interface Module is defective use the procedures in this chapter to verify the interface module performance and if necessary replace the hardware Servicing the Interface Module Troubleshooting in the HP 16505A Prototype Analyzer Environment 3 9 ...

Page 27: ...s b Open the Session Manager window then select Power Down c Remove power from the HP 16505A Prototype Analyzer then remove power from the HP 16500B mainframe d Disconnect the HP 16505A interface cable HP 16501A interface cable and LAN cable from the interface board 3 Turn off the power switch located on the front panel of the HP 16500B mainframe and the standby switch located on the rear panel Th...

Page 28: ...of the interface module connect it to the sheetmetal plate and four screws connect the rear plate of the interface module to the rear panel of the mainframe see the figure below Removing the Interface Module Servicing the Interface Module Removing and Replacing the HP 16500H Interface Module 3 11 ...

Page 29: ... to a network refer to the LAN Administartor s and Service Guide or check with your system administrator for reconnecting instructions The Ether Address of the replacement interface module will be different than the other module At powerup the HP 16500B operating system reads the address of the interface module then records the address in memory If your network configuration did not change the add...

Page 30: ...ns 2 Remove accessories from the module Only return accessories to Hewlett Packard if they are associated with the failure symptoms 3 Package the module or assemblies You can use either the original shipping containers or order materials from an HP sales office C AU TI O N Package the interface module in electrostatic material Failure to do so could cause electrostatic discharge damaging the modul...

Page 31: ... parts through a direct mail order system The advantages to the system are direct ordering and shipment from the HP Part Center in Mountain View California There is no maximum or minimum on any mail order There is a minimum amount for parts ordered through a local Hewlett Packard Sales Office when the orders require billing and invoicing Transportation costs are prepaid there is a small handling c...

Page 32: ... 66514 1 Interface Board H2 0515 0372 6 Machine Screw W1 16500 61613 1 10 40 Cable W2 16500 61614 1 Mainframe CPU Interface Board Cable This cable is only used if the HP 16500H is installed in place of an HP 16500L interface module HP 16500H Replaceable parts Servicing the Interface Module Replaceable Parts List 3 15 ...

Page 33: ...3 16 ...

Page 34: ...rders 3 14 Mainframe Test menu 3 5 O operating requirements 1 3 Option Board Test accessing 3 5 running 3 5 ordering parts 3 14 overview 1 2 P parts ordering 3 14 parts not listed 3 14 returning 3 13 performance verification failures 3 6 procedure 3 3 self test description 3 2 ping 2 5 Prototype Analyzer 2 8 R removing the interface module 3 10 3 12 replacing the interface module 3 10 3 12 require...

Page 35: ...Index 2 ...

Page 36: ...rous electric shock do not perform any service unless qualified to do so Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present If you energize this instrument by an auto transformer for voltage reduction make sure the common terminal is connected to the earth terminal of the power source Whenever it is likely that the ground...

Page 37: ...usive remedies Hewlett Packard shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any other legal theory Assistance Product maintenance agreements and other customer assistance agreements are available for Hewlett Packard products For any assistance contact your nearest Hewlett Packard Sales Office Certification Hewlett Packard...

Page 38: ...o 231 Series M 89 EMC CISPR 11 1990 EN 55011 1991 Group 1 Class A IEC 801 2 1991 EN 50082 1 1992 4 kV CD 8 kV AD IEC 801 3 1984 EN 50082 1 1992 3 V m 1kHz 80 AM 27 1000 MHz IEC 801 4 1988 EN 50082 1 1992 0 5 kV Sig Lines 1 kV Power Lines Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC Colorado Spr...