75
Usage guidelines
Configure RADIUS attribute rejection rules for the following purposes:
•
Delete attributes from the RADIUS packets to be sent if the destination RADIUS server does
not identify the attributes.
•
Ignore unwanted attributes in the RADIUS packets received from a RADIUS server.
The RADIUS attribute rejection rules take effect only when the RADIUS attribute translation feature
is enabled.
A RADIUS attribute can be rejected only by one criterion, packet type or direction.
If you do not specify a RADIUS attribute, the
undo
attribute
reject
command deletes all RADIUS
attribute rejection rules.
Examples
# In RADIUS scheme
radius1
, configure a RADIUS attribute rejection rule to delete the Connect-Info
attribute from the RADIUS packets to be sent.
<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] attribute reject Connect-Info sent
Related commands
attribute translate
attribute remanent-volume
Use
attribute remanent-volume
to set the data measurement unit for the Remanent_Volume
attribute.
Use
undo attribute remanent-volume
to restore the default.
Syntax
attribute remanent-volume unit
{
byte
|
giga-byte
|
kilo-byte
|
mega-byte
}
undo attribute remanent-volume unit
Default
The data measurement unit is kilobyte for the Remanent_Volume attribute.
Views
RADIUS scheme view
Predefined user roles
network-admin
mdc-admin
Parameters
byte
: Specifies the unit as byte.
giga-byte
: Specifies the unit as gigabyte.
kilo-byte
: Specifies the unit as kilobyte.
mega-byte
: Specifies the unit as megabyte.
Usage guidelines
Make sure the measurement unit is the same as the user data measurement unit on the RADIUS
server.