97
Predefined user roles
network-admin
mdc-admin
Usage guidelines
An HPE IMC RADIUS server uses session-control packets to deliver dynamic authorization change
requests or disconnection requests to the device. The session-control feature enables the device to
receive the RADIUS session-control packets on UDP port 1812.
This feature must work with HPE IMC servers.
Examples
# Enable the RADIUS session-control feature.
<Sysname> system-view
[Sysname] radius session-control enable
radius-server test-profile
Use
radius-server test-profile
to configure a test profile for detecting the RADIUS server status.
Use
undo radius-server test-profile
to delete a RADIUS test profile.
Syntax
radius-server test-profile
profile-name
username
name
[
password
{
cipher
|
simple
}
string
]
[
interval
interval
]
undo radius-server test-profile profile-name
Default
No RADIUS test profiles exist.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
profile-name
: Specifies the name of the test profile, which is a case-sensitive string of 1 to 31
characters.
username
name
: Specifies the username in the detection packets. The
name
argument is a
case-sensitive string of 1 to 253 characters.
password
: Specifies the user password in the detection packets. If you do not specify a user
password, the device randomly generates a user password for each detection packet. As a best
practice, specify a user password. RADIUS server might mistake detection packets that contain
randomly generated passwords as attack packets.
cipher
: Specifies a password in encrypted form.
simple
: Specifies a password in plaintext form. For security purposes, the password specified in
plaintext form will be stored in encrypted form.
string
: Specifies the password. Its plaintext form is a case-sensitive string of 1 to 63 characters. Its
encrypted form is a case-sensitive string of 1 to 117 characters.
interval
interval
: Specifies the interval for sending a detection packet, in minutes. The value range
for the
interval
argument is 1 to 3600, and the default value is 60.