![HP FlexNetwork 5130 HI series Command Reference Manual Download Page 27](http://html.mh-extra.com/html/hp/flexnetwork-5130-hi-series/flexnetwork-5130-hi-series_command-reference-manual_165888027.webp)
19
Predefined user roles
network-admin
Usage guidelines
With the
flow-control receive enable
command configured, an interface can receive, but not send,
flow control frames. When the interface receives a flow control frame from its peer, it suspends
sending packets to the peer. When traffic congestion occurs on the interface, it cannot send flow
control frames to the peer.
To handle unidirectional traffic congestion on a link, configure the
flow-control receive enable
command at one end, and the
flow-control
command at the other. To enable both ends of the link to
handle traffic congestion, configure the
flow-control
command at both ends.
Examples
# Enable Rx mode generic flow control on GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] flow-control receive enable
Related commands
flow-control
flow-interval
Use
flow-interval
to set the interface statistics polling interval.
Use
undo flow-interval
to restore the default interval.
Syntax
flow-interval interval
undo flow-interval
Default
The interface statistics polling interval is 300 seconds.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
interval
: Sets the statistics polling interval, in seconds. The interval is in the range of 5 to 300 and
must be a multiple of 5.
Examples
# Set the statistics polling interval to 100 seconds on GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] flow-interval 100
interface
Use
interface
to enter interface view.
Summary of Contents for FlexNetwork 5130 HI series