253
# In IRF mode, set the low-temperature threshold for hotspot sensor 1 on the card in slot 1 on IRF
member device 1 to –10°C (14°F), the warning threshold to 70°C (158°F), and the alarming
threshold to 90°C (194°F).
<Sysname> system-view
[sysname] temperature-limit chassis 1 slot 1 hotspot 1 -10 70 90
time at
Use
time at
to specify an execution date and time for a non-periodic schedule.
Use
undo time
to delete the execution date and time configuration for a non-periodic schedule.
Syntax
time at
time date
undo time
Default
No execution time or date is specified for a non-periodic schedule.
Views
Schedule view
Predefined user roles
network-admin
mdc-admin
Parameters
time
: Specifies the schedule execution time in the
hh:mm
format, where
hh
is in the range of 0 to 23,
and
mm
is in the range of 0 to 59.
date
: Specifies the schedule execution date in the
MM/DD/YYYY
or
YYYY/MM/DD
format. The
YYYY
value is in the range of 2000 to 2035, the
MM
value is in the range of 1 to 12, and the
value
range for
DD
depends on the month value.
Usage guidelines
The specified time (date plus time) must be later than the current system time.
The
time at
command, the
time once
command, and the
time repeating
command
overwrite one
another. The most recently configured command takes effect.
Examples
# Configure the device to execute schedule
saveconfig
at 01:01 a.m. on May 11, 2015.
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time at 1:1 2015/05/11
Related commands
scheduler schedule
time once
Use
time once
to specify one or more execution days and the execution time for a non-periodic
schedule.
Use
undo time
to delete the execution day and time configuration for a non-periodic schedule.