57
Displaying the power supply system information about your
switch
Use the
display power-supply
command to display power supply system information about your switch,
including whether power management is enabled, the number of configured redundant power supplies,
power, output voltage and current, and whether each card is powered on.
# Display detailed information about the power supply system.
<Sysname> display power-supply verbose
Power info on chassis 0:
System power-supply policy: enable
System power-module redundant(configured): 1
System power usable: 4000 Watts
System power redundant(actual): 0 Watts
System power allocated: 3620 Watts
System power available: 380 Watts
System power used(current): 1070.00 Watts
System power monitoring unit 1:
Software version: 200
Type In/Out Rated-Vol(V) Existing Usable Redundant(actual)
---------- ------ ------------ -------- ------ -----------------
PSE9000-A AC/DC 220(default) 2 2 0
DC output voltage information:
Tray Value(V) Upper-Threshold(V) Lower-Threshold(V) Status
---- -------- ------------------ ------------------ -------
1 50.00 52.00 48.00 Normal
DC output current information:
Total current(A): 21.40
Branch Value(A)
------ --------
1/1 11.80
1/2 9.60
1/3 N/A
1/4 N/A
1/5 N/A
1/6 N/A
1/7 N/A
1/8 N/A
PSU Status:
ID Status Input-Err Output-Err High-Temperature Fan-Err Closed Current-Limit
--- ------- ----------- ---------- ---------------- ------- ------ -------------
1/1 Normal
1/2 Normal